Black & Decker MULTI-GAS DETECTORS Manuale Utente Pagina 21

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
Vedere la pagina 20
BW Defender2
User Manual
10
Activating the Detector
To activate the detector, press A in a normal
atmosphere (20.9% oxygen).
Self-Test
The detector performs the actions in steps 1-10. Manually
check that all actions occur.
1. If the battery is low, I LOW flashes, the display
reads OFF. Replace the battery and restart the
detector.
2. The display shows all elements.
3. The detector beeps and flashes.
4. The detector briefly turns on the backlight.
User Downloadable model only (5 and 6)
5. The detector tests data card. Display advises if
card is present and ready for use (page 11).
6. The display shows the time, day and date.
7. The display shows the LTEL (TWA), Low and High
Alarm setpoints.
Note: The alarm setpoints on a shipped detector may vary by
region. See Resetting Gas Alarm Setpoints.
8. Calibration status is shown
9. The display reads tESt (test) as the detector tests
the sensors.
10. The oxygen sensor is calibrated automatically.
If the detector fails steps 1-10, see the section, “If the
Detector Does Not Work.”